cctamap.comKnown limitations
← Back to the map

Known limitations

Updated 2026-10-28 · 8 open · 11 resolved

This page lists the known limitations of the cctamap.com tools: what they do not get right yet (open) and what has already been fixed (resolved), with the version and date of the fix.

The open ones warn next to the result when a case activates them: the map shows «⚠ Known limitation #X» under the category and adds the same line to the draft. The warning does not change the category or the report.

The tool is an educational draft: it does not analyze images, it is not a medical device and it does not replace clinical judgment. Verify everything against the original study.

Open (8)

Each one warns next to the result when the case activates it.

Known limitation #4 L04

Medium severity · CAD-RADS 2.0 map · Open since

The automatic P leaves out plaque kept aside in N segments: it does not count in the SIS. Check the P manually.

Known limitation #7 L07

Low severity · CAD-RADS 2.0 map · Open since

With a «Direct:» result the CT-FFR value is not kept (pressing it clears a typed value): the impression records neither the value nor any discordance. Add them when editing the draft.

Known limitation #8 L08

Low severity · CAD-RADS 2.0 map · Open since

With the slider, the report writes only the figure (stenosis, restenosis or graft), without the grade term or range. Add them when editing the draft.

Known limitation #9 L09

Low severity · CAD-RADS 2.0 map · Open since

Of two lesions in one segment only the higher grade is described unless the other has features, and a plaque without stenosis loses its type. Describe them when editing the draft.

Known limitation #10 L10

Low severity · CAD-RADS 2.0 map · Open since

A lesion drawn across a segment boundary is recorded in both segments with the same grade and features. Check the grade of each segment.

Known limitation #11 L11

Low severity · CAD-RADS 2.0 map · Open since

The impression names the distal LCx segment «LCx mid-distal» (SCCT 2026 has no mid LCx). Write «LCx distal» when editing the draft.

Known limitation #13 L13

Low severity · CAD-RADS 2.0 map · Open since

With right dominance the map does not show the L-PLB (segment 18): a lesion in a posterolateral branch of the LCx cannot be marked and does not count in the category or the SIS. If there is one, add it when editing the draft and check the category.

Known limitation #19 L19

Medium severity · CAD-RADS 2.0 map · Open since

A lesion marked with a single tap on the segment that holds the anastomosis of a patent graft has no position: the map cannot tell whether it lies proximal to the anastomosis (bypassed, not coded) or at or beyond it (coded), so it counts it in the category. Drag along the vessel to draw where it lies, and check the category.

Resolved (11)

They keep the text of the warning as it was before the fix.

Known limitation #1 L01

High severity · CAD-RADS 2.0 map · Resolved on · version v1.1

With a patent graft, lesions distal to the anastomosis are not counted (e.g. 1/P2/G instead of 4A/P2/G). Assign the category manually.

Known limitation #2 L02

Medium severity · CAD-RADS 2.0 map · Resolved on · version v1.1

Marking N deletes the plaque in that segment (including native plaque outside a stent); removing N does not restore it, and SIS/P/report change.

Known limitation #3 L03

Medium severity · CAD-RADS 2.0 map · Resolved on · version v1.1

A narrowing without plaque (anomaly, intramural course, bridge, dissection) is not graded: e.g. 0/E instead of 3/E; drawn as a lesion it is written as plaque and adds P1.

Known limitation #5 L05

Medium severity · CAD-RADS 2.0 map · Resolved on · version v1.1

The report prints a systolic compression value (45% by default) even if compression was not assessed.

Known limitation #6 L06

Medium severity · CAD-RADS 2.0 map · Resolved on · version v1.1

Graft stenosis set with a button prints an internal number, not a measurement or range.

Known limitation #12 L12

Low severity · CAD-RADS 2.0 map · Resolved on · version v1.2

The ramus intermedius is present by default and, with unmarked segments described as normal, the report describes it as normal although nobody marked it. If there is no ramus, switch off «Ramus intermedius present».

Known limitation #14 L14

Medium severity · CAD-RADS 2.0 map · Resolved on · version v1.1

Clicking the first ~20% of the LAD with a mouse may open the LCx/RI instead.

Known limitation #15 L15

High severity · SYNTAX score · Resolved on · version v0.2

SYNTAX and CAD-RADS share the code format: a SYNTAX case opened in CAD-RADS invents high-risk plaque features.

Known limitation #16 L16

Medium severity · SYNTAX score · Resolved on · version v0.2

A total occlusion drawn across several segments is weighted ×5 in each segment.

Known limitation #17 L17

Medium severity · Kawasaki map · Resolved on · version v1.1

Numbers typed with non-ASCII digits or separators (Arabic, Devanagari, full-width) are truncated or ignored.

Known limitation #18 L18

Medium severity · CT protocol assistant · Resolved on · version 2026-10-27

Pre-TAVI contrast volume has no weight-based ceiling or warning.

← Back to the map